The CBP-WW4 CalBench is a package for testing and calibrating electrical, pressure, and temperature instrumentation. The selection of modules and accompanying products provide users with a flexible and high performance workstation. It can be operated manually or utilised for software driven calibration.
The 8060+ module situates centrally in the console, providing source, simulation and measurement of process signals, HART communication and 24 V loop power. It features an integral multimeter, and a PC control centre with 12.1” touch screen display. EasyCal software is pre-loaded and communicates with pressure modules and the dry block calibrator, enabling automated calibration and test management. The 5025E benchtop multifunction calibrator connects to the control centre, and provides a solution for calibrating engineer test tools like multimeters and clamp meters.
For pressure calibration, high accuracy digital gauge modules feature. For pneumatic workload a regulated module is used for vacuum to 7 bar. An electrical vacuum pump is supplied, and line pressure is typically from plant/shop air. For higher pressures gauge only modules are used with supplied pneumatic and hydraulic pumps. Further modules include fixed and variable DC and AC power supplies, and a control centre operated oscilloscope module. Storage is provided by an under bench drawer unit, perfo panel hooks, shelf, and parts bins. Calibration accessories include a pressure manifold, adaptors set, and dry block calibrator.
Features
- Instrument & electrical CalBench package
- Process calibrator/multimeter/PC module
- Source/measure V, I , Ω, Hz, temperature
- Benchtop electrical multifunction calibrator
- Regulated pressure calibrator module
- 3 precision pressure measurement modules
- Fixed and variable DC power supply modules
- Control centre operated oscilloscope module
- Variable AC power supply module
- Dry block calibrator for up to 660 °C
- Pneumatic & hydraulic pumps, manifold, adaptor set
- EasyCal calibration software, peripherals supplied
Pressure Calibration
The CBP-WW4 features four main pressure modules for calibration work. These include a regulated module covering vacuum to 7 bar (100 psi), utilised with line pressure. Three precision measurement modules provide further calibration coverage for 20 bar (300 psi), 100 bar (1500 psi) and 700 bar (10,000 psi). These are used with the supplied pneumatic and hydraulic pumps. Calibrate pressure instrumentation such as:
- Analogue and digital gauges, indicators, manometers
- Calibrators, sensors, transducers, transmitters
- Switches, valves, controllers, chart recorders
Electrical Calibration
The package includes electrical sourcing functionality with the 5025E multifunction calibrator, and modules for measurement applications. It provides users with automated calibration capabilities to cover a wide range of electrical and electronic equipment including:
- Multimeters, analogue meters, clamp meters, data loggers
- Calibrators, decade boxes, conductance meters, tachometers
- Power meters, watt meters, power supplies
Temperature Calibration
The CBP-WW4 enables users to perform efficient calibration of temperature instrumentation. EasyCal can control the dry block calibrator whilst reading back the temperature measurement of the sensor under test on the 8060 module. Calibrate various products including:
- Sensors, transmitters, indicators, thermometers
- RTDs, thermocouples, recorders, controllers
- Process calibrators, PRTs, thermistors
EasyCal Calibration Software
The CBP-WW4 comes with EasyCal software on the 8060 control centre. This enables software driven testing procedures and provides increased speed of calibration and consistency of results.
Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.

Details
Downloads
| File Name | File Size | Language | Format |
|---|---|---|---|
|
600 kB |
EN |
|
|
11.5 MB |
EN |
|
Request a price quote
CBP-WW4 CalBench Package
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact