A range of CalBench modules that include temperature calibrators and simulators for RTD and Pt100 applications loop calibrators, process communicators and more. These modules are commonly used on the bench when testing transmitters, transducers and sensors.
These modules combine practicality with simple operation for instrumentation testing and diagnostics. For automated calibration the comprehensive 8060 multifunction calibrator and control centre provides the optimal solution for process signal source and measure on the CalBench.
-
8060 Multifunction Process Calibrator and Control Centre
- Source mV, mA, resistance & frequency
- Measure mV, mA, resistance & frequency
- Thermocouple simulate/measure (13 types)
- RTD simulate and measure (11 types)
- Touch screen control centre, 12.1” display
- Integral 24 V loop power supply
- Optional integral 6.5 digit multimeter
View Data Sheet -
7085A Temperature Distribution & Scanner
- 10 channel scanner for batch T/C testing
- Cold junction temperature display
- Records min/max ambient temperatures
- Interfaces with 8060+ or 7051+ modules
- Can be used with 5065B multimeter module
- Clear visual display of temperature (LCD)
- Suitable for use with dry block calibrators
View Data Sheet -
7001 Pt100 Simulator
- -200°C to +800°C
- Accuracy ± 0.3°C
- 23 set points
- Temperature coefficient <30ppm/°C
- ITS-90 EN60751
- Exceeds class A
- Passive resistance source
View Data Sheet -
7067 Loop Calibrator
- Loop source/measure V or I
- Measure 0 to 25 V or 0 to 125 mA
- Source 0 to 21 V or 0 to 50 mA
- Accuracy 0.01 %
- Resolution 1 μA or 1 mV
- Programmable ranges
- Manual step, auto-step & ramp
View Data Sheet -
7068 RTD Temperature Calibrator
- 0.05 °C accuracy, 0.01 °C resolution
- 0.03 Ω accuracy, 0.01 Ω resolution
- 2, 3 and 4 wire connections
- Read and simulate °C, °F, °K, Ω
- Ramp and step
- Pt100 plus 7 other RTD types
- User programmable
View Data Sheet -
7069 Voltage/Current/Loop Calibrator
- Source/measure voltage & current
- 3 source ranges to 22 mA or 22 V
- 3 measure ranges to 70 mA or 50 V
- Accuracy 0.02 % of span
- Transmitter simulator/sink
- Output steps and ramps
- Fine adjustment (inching)
View Data Sheet -
7077 Process Calibrator
- Measure/simulate thermocouples
- Measure/simulate Pt100
- Measure/source (µV/mV/mA)
- Display in °C and °F
- Automatic CJC - selectable
- 10 point memory recall
- Process loops 4-20mA/0-50mA
View Data Sheet -
7079 Loop Ancilliaries Calibrator
- Loop measure 0 to 200 mA
- 0.05 % accuracy, 10 μA resolution
- 4.5 digit display
- Continuity test
- 24 V output, power 4 to 20 mA loops
- Overload protection to loop
- RS-232 interface
View Data Sheet -
7002-7003-7004 Hart & Fieldbus Modules
- 7002 HART communication module
- 7003 FF communication module
- 7004 Combined HART & FF module
- EasyCal applications for HART & FF
- Smart device calibration & verification
- Monitoring of primary values
- Conditioned power
View Data Sheet
EN
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact