5075B Multímetro digital

  • Descripción
  • Especificaciones
  • Descargas
  • Cotización
5075B Multímetro digital

A digital multimeter module that combines high performance and accuracy with simple operation.
With speed and precision, the 5075B easily measures from nanovolts to 10kV, from picoamps to 30 Amps, from nano-ohms up to 1GΩ, and from picofarads to 300μF. It is ideal for users requiring a cost-effective DMM with multiple functions and exceptional resolution and accuracy up to 7½ digits. This makes the 5075B is a versatile solution to essential laboratory calibration and verification, covering a wide range of applications with excellent measurement capabilities, whilst maintaining reliability and performance.

The Auto Dynamic Filter (ADF) mode allows the 5075B to automatically select the most suitable filter. For a fast changing signal or for when the signal is first connected the reading is displayed almost immediately, but if the input remains constant, the filter time is increased to provide a more stable accurate reading. If the input were disconnected the filter would immediately return to the fastest.

Operation is simple, all major functions from range selection to null require just one key press. The large 24 digit display shows clearly the range and reading and can even show the time to the next sample if required. Other functions can be easily selected from a scrolled menu.

Functions for diode/zener tests, max/min, peak hold and continuity checks are available and also various audible warnings can be selected.

A bar graph function allows the user to program high and low pass/fail limits and switch to the bar display mode. This will give an audible and visual indication to the user of the components specification.

A low thermal, 10-channel scanner option, allows multiple inputs to be displayed or compared without the additional cost and inconvenience of a separate switching arrangement.

EasyCal Software - Manage, Automate and Optimise the Calibration Process
To automate the calibration process the 5075B can be controlled using Time Electronics’ EasyCal software. This provides increased speed of calibration and consistency of results. Easily produce calibration certificates and reports to ISO 9001, ISO 17025, and other international quality standards.

Características

  • Resolución de 7½ dígitos
  • Voltaje CA/CC &erio; actual
  • Resistencia & temperatura
  • Capacitancia & frecuencia
  • Precisión de 18 ppm/año
  • Opción de escáner de 10 canales
  • Compatible con el software EasyCal

Especificaciones

Especificación técnica
Especificación general
Opciones

Descargas

Nombre del Archivo Tamaño del Archivo Idioma Formato

5075B Módulo multímetro digital ficha técnica

673 kB

EN

PDF

Solicite una cotización

5075B Multímetro digital

0.00
ES