- Accueil
- Produits
- Calibrateurs de procédé portables pour l’étalonnage
- 7198 : Pressure Calibration Accessories Kit
7198 : Pressure Calibration Accessories Kit
![7198 : Pressure Calibration Accessories Kit](/fr/calibrateurs-de-procede-portables/image/l/7198-pressure-calibration-accessories-kit.jpg)
Caractéristiques Principales
- Adaptors/fittings/connectors/hoses
- Metric/BSP/parallel/NPT adaptors
- Coupling connectors
- Quick release & minimess hoses
- 10" adjustable spanner included
- Suitable for use with pumps
- Compact kit for labs & on-site work
The 7198 is a comprehensive selection of pressure adaptors, manufactured from stainless steel. Together with a range of accessories and hoses, the 7198 enables rapid connection of pressure instrumentation during calibration and test applications.
Housed in a rugged plastic case, the kit comprises of BSP (parallel), NPT (tapered) and metric threads, with both male and females threads terminated by a ¼ BSP male. The use of ¼ BSP (female) couplers allows unlimited combinations of threads to accommodate any possible requirement.A combination of low pressure hoses with quick connectors and high pressure Minimess 1620 hoses ensure complete connectivity between the pressure source and the unit under test.The 7198 is suitable for use with the Time Electronics CalBench and with pressure generating devices such as portable and benchtop pressure pumps. Compact and practical, the 7198 offers a quick solution to pressure component requirement in both the field and laboratory.Adaptors 1/4 BSP Maleto Metric1 off M10 x 1.0 Female
1 off M10 x 1.0 Male1 off M12 x 1.0 Female1 off M12 x 1.0 Male1 off M12 x 1.25 Female1 off M12 x 1.25 Male1 off M14 x 1.5 Female1 off M14 x 1.5 Male1 off M16 x 1.5 Female1 off M16 x 1.5 Male1 off M20 x 1.5 Female1 off M20 x 1.5 MaleBSP
1 off 1/8 BSP G Female
1 off 1/8 BSP G Male
1 off 1/4 BSP G Female
1 off 1/4 BSP G Male
1 off 3/8 BSP G Female
1 off 3/8 BSP G Male
1 off 1/2 BSP G Female
1 off 1/2 BSP G Male
1 off 1/8 BSP R Female
1 off 1/8 BSP R Male
1 off 1/4 BSP R Female
1 off 1/4 BSP R Male
1 off 3/8 BSP R Female
1 off 3/8 BSP R Male
1 off 1/2 BSP R Female
1 off 1/2 BSP R Male1/4 BSP Maleto BSP1 off 1/8 BSP G Female
1 off 1/8 BSP G Male4 off 1/4 BSP G Female1 off 1/4 BSP G Male1 off 3/8 BSP G Female1 off 3/8 BSP G Male2 off 1/2 BSP G Female1 off 1/2 BSP G Male1 off 1/8 BSP Rc Female1 off 1/8 BSP R2 Male1 off 1/4 BSP Rc Female1 off 1/4 BSP R2 Male1 off 3/8 BSP Rc Female1 off 3/8 BSP R2 Male1 off 1/2 BSP Rc Female1 off 1/2 BSP R2 Male1/4 BSP Maleto NPT2 off 1/8 NPT Female
1 off 1/8 NPT Male4 off 1/4 NPT Female1 off 1/4 NPT Male1 off 3/8 NPT Female1 off 3/8 NPT Male1 off 1/2 NPT Female1 off 1/2 NPT MaleAdditional 2 off Minimess 1/4 BSP G Male
1 off 4mm OD Hose pushfit M
1 off 4mm OD Hose pushfit FHoses and Extras Hoses
1 off Minimess to Minimess 1m
1 off Minimess to Minimess 0.5m1 off Minimess to 1/4G 1m2 off QR Plug to Socket 550mm2 off QRC Plug to Plug 550mm2 off QRC Socket to Socket 550mm1 off 2m of 6mmExtras
2 off 6mm hose push fit to 1/4 BSP G M
2 off 4mm hose push fit to 1/4 BSP G M4 off Quick release plug to 1/4 BSP G M4 off Quick release socket to 1/4 BSP G M2 off Y-piece 1/4 BSP G F2 off Quick release socket to 6mm hose2 off Quick release plug to 6mm hose4 off 1/8 dowty bonded washer8 off 1/4 dowty bonded washerTools and Cases
1 off 10” Adjustable Spanner
1 off roll of PTFE tape1 off Case with foam inserts for adaptors, central partition and compartment for additional items.Definition of types of adaptors according to EN 10226 or ISO 7:
• G = external + internal parallel (ISO 228)• R = external taper (ISO 7)• Rp = internal parallel (ISO 7/1)• Rc = internal taper (ISO 7)• Rs = external parallelGeneral InformationCase Dimensions: 392 x 313 x 190mm / Case Weight: 7.18kgShipping Information:Packed Dimensions: 410 x 215 x 350mm / Packed Weight: 7.68kgModèles 7198
Pressure Calibration Accessories Kit
Téléchargements PDF Nom du fichier Taille du fichier Langue 1.2MB
EN
Appel d'offre
7198 : Pressure Calibration Accessories Kit
Produits connexes
-
7016 : Calibrateur Régulé de Faibles Pressions
- Faibles pressions régulées
- versions vide à 20bar
- Précision : 0,04% de la pleine échelle
- Pneumatique
- Alimentation de boucle 24/36V
- Mesure du courant de boucle
- Alarme de surpression
-
Bancs d'étalonnage
- Station de calibration multifonctions
- Modules d'étalonnage
- Pression, temperature, tension et courant
- Mesure et génération de résistance
- Mesure et génération de fréquence
- Mesure et simulation de thermocouples & RTDs
- Modules d'alimentation électrique