Products commonly used in this industry
-
1044 Voltage and Current Calibrator
- Measure voltage and current
- Source voltage and current
- 3 voltage ranges 0 to 20 V
- 3 current ranges 0 to 20 mA
- Accuracy 0.05 %
- 3.5 digit LCD display
- Portable with 28 hours typical battery life
-
1051 Resistance Decade Box
- 0.01 Ω to 1 MΩ
- High accuracy and stability
- Simple operation with clear visual indication
- Suitable for Pt100 simulation
- Low temperature coefficient
- Safety terminals
- Removable protective cover
-
1040 Resistance Decade Box
- 1 Ω to 100 MΩ
- High accuracy
- Clear visual indication
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
-
1041 Resistance Decade Box
- 0.01 Ω to 1 kΩ
- 10 mΩ resolution
- Ideal for PRT and RTD
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
-
1049 Pt100 Simulator
- –200 °C to +800 °C
- ± 0.3 °C accuracy
- Based on ITS 90 EN 60751
- 23 set points
- Exceeds class A
- Good temperature stability
- Passive resistance source
-
1053 Inductance Decade Box
- 1 mH to 10 H
- In-line readout
- 3 % accuracy
- High stability
- Safety terminals
- Fully screened
- Robust and portable
-
1061 Resistance Decade Box
- 1 Ω to 1.2 MΩ
- In-line readout
- Stable metal film resistors
- Mechanically and electrically robust
- Ideal for education and electronics
- Safety terminals
- Fully screened
-
1071 Capacitance Decade Box
- 10 pF to 100 μF
- 1 % accuracy
- In-line readout
- Colour coded digits
- Safety terminals
- Bi-polar working
- Supplied with protective cover
-
5018 Programmable DC/AC V/I Calibrator
- 0 to 22 V DC
- 220 V and 1 kV DC options
- 0 to 220 mA AC/DC options
- 0 to 22 V AC option
- Ramping feature
- GPIB / RS-232 / USB interfaces
- Ideal for ATE applications
-
5065 6.5 digit Multimeter
- DC V to 1000 V, AC V to 750 V
- AC/DC current to 3 A
- Two and four wire resistance
- Frequency from 3 Hz to 300 kHz
- Period and diode measurement
- Temperature measurements
- USB interface, optional GPIB
-
CalBench Calibration Benches
View CalBench- Universal calibration systems
- Electrical/pressure/process
- Power supplies, DMMs & scopes
- Multifunction calibrator modules
- Ideal for on-site test facilities
- Automatic or manual calibration
- Complete lab design service
-
7006 Loop Simulator & Source
- 4 to 20 mA or 0 to 10 V loops
- 7 calibration set-points
- Accuracy 0.1 %
- TxSim and RxTest modes
- Autostep output - adjustable rate
- Battery powered PP3
- Internal loop drive supply
-
7040 Digital Pressure/Current Calibrator
- Vacuum to 20 bar versions
- 0.04 % accuracy
- Loop current calibration
- 9 engineering units
- Min / Max function
- Leak rate function
- RS-232 serial interface
-
7090 Pneumatic Calibration Pump
- Pressure to 40 bar (600 psi)
- Vacuum to -950 mbar
- Oversized check valve
- Contoured cushioned handles
- Protective caging for vent valve
- Hose, fittings, & carry case supplied
- Optional digital gauges
-
8100 Instrumentation Test Stand
View 8100- Multi-purpose test stand
- For process & pressure instrumentation
- Configurable solution for workshop use
- 2 transmitter poles for U-bolt connections
- Pressure manifold with quick connect port
- Quick-vice with sliding jaw
- Retort rod for RTDs and thermocouples