Products commonly used in this industry
-
5075 7.5 digit Multimeter
View 5075- 7.5 digit resolution
- AC/DC voltage and current
- Resistance and temperature
- Capacitance
- Frequency
- 18 ppm best accuracy
- 10 channel scanner option
-
5025C Multifunction Calibrator
View 5025C- 15 ppm precision calibrator
- 0 to 1050 V AC/DC voltage
- 0 to 22 A AC/DC current
- 1 Ω to 1.1 GΩ variable resistance
- Thermocouple and Pt100 simulation
- Clamp meter and power calibration
- Capacitance and inductance
-
1044 Voltage and Current Calibrator
- Measure voltage and current
- Source voltage and current
- 3 voltage ranges 0 to 20 V
- 3 current ranges 0 to 20 mA
- Accuracy 0.05 %
- 3.5 digit LCD display
- Portable with 28 hours typical battery life
-
1051 Resistance Decade Box
- 0.01 Ω to 1 MΩ
- High accuracy and stability
- Simple operation with clear visual indication
- Suitable for Pt100 simulation
- Low temperature coefficient
- Safety terminals
- Removable protective cover
-
1040 Resistance Decade Box
- 1 Ω to 100 MΩ
- High accuracy
- Clear visual indication
- High stability
- Safety terminals
- Low temperature coefficient
- Supplied with protective cover
-
1053 Inductance Decade Box
- 1 mH to 10 H
- In-line readout
- 3 % accuracy
- High stability
- Safety terminals
- Fully screened
- Robust and portable
-
1065 Power Resistance Decade Box
- 0.1 Ω to 120 kΩ
- 1 % accuracy
- 10 W total dissipation for any setting
- Residual resistance < 20 mΩ
- In-line readout
- Mechanically/electrically robust
- Fully screened
-
1067 Precision Resistance Decade Box
- 10 mΩ to 12 kΩ
- 0.01 % accuracy
- Precision Pt100 simulation
- 6 digit resolution
- Better than 20 ppm/year stability
- Residual resistance < 10 mΩ
- Fully screened
-
5011 Resistance / Temperature Calibrator
View 5011- 1 Ω to 120 MΩ
- RTD and thermocouple simulation
- DCV and DCI options
- 10 MHz frequency option
- RS-232 / GPIB / USB interfaces
- Front panel operation
- EasyCal Software compatible
-
5018 Programmable DC/AC V/I Calibrator
- 0 to 22 V DC
- 220 V and 1 kV DC options
- 0 to 220 mA AC/DC options
- 0 to 22 V AC option
- Ramping feature
- GPIB / RS-232 / USB interfaces
- Ideal for ATE applications
-
5065 6.5 digit Multimeter
- DC V to 1000 V, AC V to 750 V
- AC/DC current to 3 A
- Two and four wire resistance
- Frequency from 3 Hz to 300 kHz
- Period and diode measurement
- Temperature measurements
- USB interface, optional GPIB
-
5077 Multifunction Power Calibrator
View 5077- 0 to 1050 V AC/DC voltage
- 0 to 22 A AC/DC current
- Single-phase power simulation
- Up to 23 kVA or 23 kW
- Phase angle ± 90.0°
- Power factor 0.00 to 1.00
- 40 to 500 Hz adjustable frequency