![](assets/upload/images/2020/product/closer-look-large.png)
The 7010 is a robust portable pressure calibrator that is suitable for field and laboratory calibration work of both pressure and electrical process loop signals. It is a simple operation instrument ideal for calibrating and cross-checking pressure gauges, sensors, transmitters, transducers, indicators, switches, and many other devices. The following versions are available; 0.2, vacuum to 2, 5, 10, 20, 35, 70, 100, 200, 400, or 600 bar. Vacuum down to -850 mbar is possible on the 2 bar version.
For process signal calibration the loop signal is displayed on an LCD display to 0.05 % accuracy. Loop power (24 V or 36 V) is also provided. Both pressure and loop signal can be displayed at the same time to speed up the calibration of pressure transmitters. Additionally a continuity function is available for testing for open circuit loops.
The 7010 allows switch selection of four pressure units in addition to mA. Common pressure units are configured as standard (see specifications), but user-specified units can be requested. Both pressure and loop current are displayed on 4.5 digit LCD displays.
Features
- Vacuum to 600 bar versions
- Accuracy 0.04 % of full scale
- Pneumatic or hydraulic
- Over-pressure alarm
- Isolated 24/36 V loop supply
- Loop current measure
- Mains / battery power
![Portable Pressure Calibrator](assets/upload/images/feat-boxes/7010_fb_portable.webp?__ver=1628074338)
Portable Operation
Power is via internal rechargeable cells (24 hours typical use) with a built-in mains charger. The unit can be powered directly from the mains if required.
The 7010 is housed in an impact resistant safety case that provides protection and increased durability. All pressure connections are on the side of the case. The instrument is supplied with a pressure hose, electrical test lead, 2 electrical probes and 2 crocodile clips.
![7090 hand pump](assets/upload/images/feat-boxes/7010_fb_7090.webp?__ver=1628071572)
Accompanying Products
For the 7010, input pressure can be generated by external hand pumps. The 7090 pneumatic (-950mbar to 40bar), or 7095 hydraulic (0 to 700bar) pumps are ideal for this purpose. Gauges are also available.
For process signal simulation Time Electronics’ handheld 7006 Loop-Mate is available as an option. It provides 4 - 20 mA and 0 - 10 V signals at levels of 0%, 10%, 25%, 50%, 75%, 90%, 100%. It can also step through these set points automatically to allow hands free calibration. It is battery powered and can be stored in the 7010’s pouch.
EasyCal Calibration Software
The 7010 has RS-232 communication for use with Time Electronics EasyCal software. This allows users to automate the testing process for increased speed of calibration and consistency of results.
Produce traceable calibration certificates and test reports for quality standards with additional uncertainty information for ISO 17025 conformance.
![EasyCal Calibration Software](assets/upload/images/feat-boxes/easycal-calibration-software-pressure.webp?__ver=1633599235)
Specifications
Downloads
File Name | File Size | Language | Format |
---|---|---|---|
980 kB |
EN |
|
Request a price quote
7010 Single Channel Pressure Calibrator
![EN](assets/upload/images/2020/nav/Globe-small.png)
- Product Ranges
- Decade Boxes
- Portable Voltage & Current Calibrators
- Electrical Multifunction Calibrators
- ATE / Bench Calibrators & Multimeters
- Electrical Test Equipment Calibrators
- Process Calibration Instruments
- Pressure Calibration Instruments
- Calibration Benches
- Calibration Software
- Accessories
- Discontinued Products
- Products by Function
- Calibration Benches
- Industries
- Services
- Resources
- About
- Contact